1120433996

Complete collection of SQZ series water and steam sampling device coolers

The first stage used for secondary cooling of high-temperature and high-pressure sample water can withstand a high temperature difference between sample water and cooling water, and has a long service life

Online customer service:

  • Product Introduction
  • Technical Parameter

The first stage used for secondary cooling of high-temperature and high-pressure sample water can withstand a high temperature difference between sample water and cooling water, with a long service life and structural principle

The cooler is composed of inner spiral tubes. Jointly installed inside a cylinder and spirally placed in swirling cooling water for heat exchange, the two types of cooling are cleverly matched in one cooler for flow transport

characteristic

The first stage used for secondary cooling of high-temperature and high-pressure sample water can withstand a high temperature difference between sample water and cooling water, and has a long service life.

The second stage for cooling sample water with a temperature below 300 ℃ is commonly used in water and steam sampling devices for medium and small capacity thermal power units.

The second stage used for cooling high-temperature and high-pressure sample water. The appropriate length of the outer cylinder is commonly used in larger capacity thermal power units.

The second stage for cooling high-temperature and high-pressure sample water in large capacity thermal power units. The double sleeve inner and outer spiral tube structure design reduces equipment volume and cost.

The second stage used for cooling high-temperature and high-pressure sample water has a long effective length and a large effective area. The thickness of the sample water is 1.5 millimeters, which has a good cooling effect.


ModelSQZ-15SQZ-17SQZ-20SQZ-30SQZ-34SQZ-43
Heat Exchange Area(m2)0.150.170.200.300.34 0.439
Specification of sample water pipeφ12×2φ12×2φ12×2φ8×1.5φ12×2φ10×1.5
Cooling water pipe specificationsφ27×3φ27×3φ27×3φ27×3φ27×3φ22×2.5
Outer cylinder sizeφ108×334φ108×335φ108×250φ108×300φ108×460φ108×595
(External Meridian × Height) φ108×285 φ108×360φ108×535φ108×650
Sample water inlet temperature≤550℃≤570℃≤550℃≤540℃≤550℃≤560℃
Sample water outlet temperatureCooling water temperature+3℃Cooling water temperature+3℃Cooling water temperature+1.5℃Cooling water temperature+3℃Cooling water temperature+1.5℃Cooling water temperature+2℃
Sample water pressure≤32MPa≤25MPa≤32MPa≤35MPa≤32MPa≤32MPa
Sample water flow rate<3500mL/min<1500mL/min<3500mL/min<1500mL/min<3500mL/min<2600mL/min
Cooling water temperature≤30℃≤33℃≤30℃≤35℃≤35℃≤35℃
Cooling water flow rate1t/h2~3t/h1.5t/h2t/h2~3t/h1.2t/h
Cooling water pressure≥0.25MPa≥0.7MPa≥0.25MPa≥0.7MPa≥0.2MPa≥0.5MPa
Working pressure<32MPa<25MPa<32MPa<35MPa<32MPa<32MPa
Sample water pipe methodSingle wound spiral typeSingle wound spiral typeDouble wound coil typeDouble wound coil typeDouble wound coil typeDouble wound coil type